Data Center ni hta pat da ai nbung katsi ai nta ni hpe jai lang ai lam
Mar 19, 2026
Shiga hpe tawn da u

Server ni hpe-density kaba ai hku galaw ai majaw, data center ni gaw shaning ting hta ngang grin ai nbung hpe shapraw kau ra ai. Closed circulation, n-gun kaba ai nbung galai shai ai lam, hka hpe makawp maga ai hte n-gun hpe hkye la ai zawn re ai shanhte a akyu ni a majaw, hpaw da ai circuit cooling tower ni gaw green data center ni hta cooling system ni a matu madung hparan ladat langai byin tai wa sai, IDC kaba hte lapran tsang-sized IDC ni hte AI computing center ni hta mung grai law hkra jai lang mai nga ai.

Hkring mat ai circuit katsi ai nta ni hpe hkap la aicoil- hpe madung tawn nna pat da ai n-gun galai shai ai hkrang: computer nta kaw na n-gun ja ai-katsi ai hka gaw, nta npawt kata na stainless steel coil ni de shang wa nna, shinggan na hka lim ai hka gaw coil ntsa ni hpe maren mara ka-up da ai. Fans ni gaw katsi ai hpe shapraw kau na matu nbung hpe hkap la nna, "katsi na matu kata na shingjawng ai lam hte katsi ai hpe ningdang kau na matu shinggan na shingjawng ai lam" ngu ai katsi ai hpe galai shai ai ladat lahkawng hpe chye na la lu ai. Ndai system gaw hpaji rawng ai bungli galaw ai ladat masum hpe madi shadaw ya ai: hka lum ai aten hta, katsi na matu chillers ni hte rau bungli galaw ai; spring, autumn (sh) shana nbung katsi ai aten hta, manu jahpu n jaw ra ai sha katsi ai de galai nna, katsi ai hpe hkrak jaw ya ai; galai shai ai aten ni hta, pre-cooling mode hpe hkap la ai, dai hta hka hpe chiller ni de n shang shi yang, cooling tower hku nna shawng katsi shangun ai majaw, chiller unit ni a bungli galaw ai aten hpe grai kadun shangun ai.

Shi a madung akyu ni gaw dan dawng nga ai:Langai, n-gun atsam grai ja ai hte n-gun hpe hkye la lu ai. Katsi galai shai ai atsam gaw 82% jan du wa nna, hpaw da ai katsi ai nta ni hta 17% grau law ai. Variable frequency control hte hpawn, PUE hpe 1.15–1.25 de shayawm lu nna, shaning shagu na katsi ai n-gun lang ai lam hpe 30%–40% shayawm lu ai.Lahkawng, hka hpe grai makawp maga lu ai. Dai pat da ai hka lim ai lam gaw hka lim ai lam hte hka lim ai lam hpe shayawm ya nna, hka- hpe 60%–80% hkye la lu ai. Data center langai gaw shaning shagu hka ton 26,000 jan hpe hkye la lu ai.Masum, jak rung ni hpe makawp maga ai lam. Dai gaw nhprang wan hte acidic gases ni hpe garan ginhka ya nna, scaling hte corrosion hpe shayawm ya ai, coil ni a service life hpe 10 ning jan jat ya ai, gram lajang ai manu hpe 35% shayawm ya ai.Mali ngu na hta, ngang grin ai lam hte kam hpa mai ai lam ni hpe shayawm ya lu ai. Hka pru wa ai hka n-gun galai shai ai lam hpe ±1℃laman hta hkang lu ai, cabinet langai hta 30kW jan n-gun ja ai -density n-gun hpe shapraw kau lu ai hte AI clusters ni a ra kadawn ai lam ni hpe hkan sa lu ai.

Tatut jai lang ai lam hta, hpaw da ai circuit katsi ai nta ni hte galai kau ai hpang, Yangtze hka hkin gau na AI computing center langai gaw, katsi ai atsam hpe 62% kaw nna 83% de jat wa shangun ai, system n-gun lang ai lam hpe 48% kaw nna 35% de shayawm ya ai, shaning shagu electric kWh wan 1.2 jan hpe hkye la lu ai.
Miwa mung dingdung daw na nhpu hte nbung laru law ai shara kaw nga ai edge data center langai mi gaw FRP hpaw da ai katsi ai nta ni hpe jai lang ai majaw, n-gun n-gun 0.5% a lawu de du mat nna, shaning shagu gram lajang ai manu hpe 150,000 yuan kaw nna 80,000 yuan de shayawm kau ya ai.
Model lata na matu, N+1 redundant configuration ra ai, wet-bulb a n-gun, katsi ai n-gun hte npu lamu ga hpe myit yu nna, dry-wet dual-yaw shada lam hte hpaji rawng ai galai shai ai frequency model ni hpe ahkyak shatai nna galaw ra ai.
Data center ni a computing density law wa ai hte "dual carbon" ngu ai yaw shada lam hpe n-gun jaw ai hte maren, hpaw da ai circuit katsi ai nta ni hpe modularization, hpaji rawng ai hte hka katsi ai hpe hkap la lu ai de gram lajang na rai nna, green data center ni hta katsi ai ladat ni a matu madung madi shadaw ai lam tai wa na re.
San sagawn ai lam hpe sa dat u