Evaporative condenser gaw nbung-katsi ai condenser hta grau ai n re, mabyin masa yawng hta; langai hte langai hta hpaji masa hta akyu nga ai hte jai lang mai ai mabyin masa ni nga ai, n-gun lang ra ai lam, hka n-gun atsam masa, bungli galaw ai masa majing hpe jung da ai shara zawn re ai lam ni hpe madung tawn nna, hkum tsup ai hku dawdan ra ai. N-gun galai shai ai lam hte n-gun jai lang ai lam zawn re ai core performance dimensions ni a ningmu hku yu yang, evaporative condenser gaw ahkyak ai akyu ni nga ai, raitim nbung-katsi ai condenser gaw gram lajang ai lam hta loi ai hte shawng nnan na gumhpraw bang ai lam hta grau laklai nga ai.

Ahkyak ai aten galu-sut masa akyu rawng ai lam

Mungkan ting na mare kaba 27 hta nga ai, htaw sa ai shara 50 nga ai, 200+ ga amyu ni hpe jaw ya ai, hkying hkum 7x24 tup htaw sa lu ai atsam, hpaga yumga galaw ai lam a matu kaja dik htum ai manang re

Loaded Unit Photographs Closed-Circuit Cooling Tower Ready for Dispatch

834M

Yawng Shanglawt ai wa

732M

Kaja ai hku bai maram yu ai

90M

Order hkap la sai

236M

Project ni ngut sai

 

Customer Site Installation of Closed-Circuit Cooling Tower

Evaporative condenser a madung akyu ni gaw, nbung hpe galai shai ai lam hta n-gun atsam jai lang ai lam hpe hkang lu ai atsam nga ai. Shi gaw "hka n-gun shayawm ai + nbung n-gun shayawm ai" ngu ai n-gun galai shai ai ladat hpe hkap la nna, hka n-gun shayawm ai latent heat (2260kJ/kg) hpe jai lang nna, unit area langai hta n-gun galai shai ai lam gaw nbung hte katsi ai condenser a htam 5-8 rai nga ai.

 

Shi a hka n-gun gaw, grup yin na hka n-gun hte ni dik ai, nbung-katsi ai condenser hta 8-11℃shayawm ai, hka n-gun 1℃hkrat sum ai shaloi, hka n-gun shayawm ai jak a compressor n-gun jai lang ai lam hpe 3%-p hta grau shayawm lu ai. Nbung hte katsi ai hta na 30% yawm ai hka ja ai jak.

 

Dai hta n-ga, evaporative condenser gaw condenser, katsi ai nta, hka lim ai hka pump, etc. ni a bungli ni hpe hpawng de ya nna, nbung-katsi ai condenser a lamu ga jarit 50% daram sha shinggrup da ai majaw, center plants hte compact space su.

Front View Diagram of Closed-Circuit Cooling Tower

Hka n-gun hpe jai lang ai lam hta, evaporative condenser gaw hka n-gun loi mi sha shinggrup ra ai raitim, shi a hka jai lang ai lam gaw hka-katsi ai condenser a 5%-10% sha rai nna, htunghking hka-ol system a secondary heat dissipation loss hta grau yawm ai.

 

Hka n-gun grai law ai shara ni hta, shi a hka-hkye la ai akyu hpe naw mu lu ai. Nbung-katsi ai condenser gaw katsi ai hpe galai shai na matu nbung hpe sha kam hpa nna hka n-gun n ra ai, ndai lam gaw hka-n law ai dingdung daw ginra ni (sh) katsi ai arung arai kaji ni hta grau jai lang mai ai atsam nga ai.

 

 

Evaporative Air Cooler for Smelting

Raitim, hka lim ai condenser hta mung shadawn sharam nga ai. Shi a hkrang hta hka a hkam kaja lam a matu ra kadawn ai lam grai law ai hte scaling hte nozzle clogging byin chye ai, hka hpe ayan jasan jaseng nna gram lajang ra ai, gram lajang ai manu gaw nbung-katsi ai condenser hta grau law ai spray system hte dehydrators zawn re ai arung arai ni lawm ai.

 

Dai hta n-ga, katsi majan aten hta n-gun n law ai shara ni hta, shi a hka htung ni gaw katsi mat nna, n-gun yawm mat chye ai majaw, katsi mat ai hpe ninghkap ai ladat ni hpe jat bang ra ai majaw, bungli galaw ai lam hte hparan hpareng ai lam hta grau sawng wa ai.

evaporative coolers

Nbung-katsi ai condenser a akyu gaw, asan sha galaw ai ladat hte gram lajang ai lam hta loi ai. Dai gaw finned coils hte fans ni sha lawm ai, shawng nnan na gumhpraw n law ai, n-gun jaw ai hka circuit system n ra ai majaw, nta kata na nbung laru shazim ai jak hte katsi ai shara kaji zawn re ai kaji ai hte lapran tsang-sized refrigeration arung arai ni a matu htuk manu ai.

 

Hka-n ​​law ai tsan ai shara ni hta, nbung-katsi ai condenser gaw hka jaw ai lam hpe myit yu ra na n rai, bungli galaw ai lam hta grau n-gun ja ai. Raitim, nbung laru aten hta-katsi ai shara ni hta, shi a condensing temperature gaw 50℃du hkra rai nna, katsi ai atsam grai hkrat sum mat na re majaw, katsi ai atsam hpe hkam la lu na matu compressor atsam hpe jat ra ai majaw, aten galu-bungli galaw ai n-gun grai law hkra jai lang ra ai.

 

 

Why Are Closed-Circuit Cooling Towers More Reliable?

Tsun ga nga yang, evaporative condenser gaw, n-gun lang ai lam hte shara a matu grai ngang kang ai ra kadawn ai lam ni nga ai, hka n-gun hpe jasan jaseng ai masa ni hpe hkan sa lu ai shara ni hta, kaba ai-industrial refrigeration system ni, data center ni hte kaga mabyin masa ni hta jai lang ai shaloi, grau kaja ai hkum tsup ai bungli galaw lu ai; nbung-katsi ai condenser gaw, hka ja ai arung arai kaji ni, hka-n law ai shara ni hta asan sha katsi ai jak ni, shing nrai, manu n law ai hte gram lajang na matu loi ai bungli masa ni hpe hkan tam ai bungli masa ni a matu grau htap htuk ai lata la ai lam rai nga ai.

 

 

 

 

 