kacGa

Na a katsi ai nta hpe katsi majan galaw ai: Ahkyak ai katsi makawp maga lam matsun

Sep 08, 2026

Shiga hpe tawn da u

Cold Wave Alert: Essential Winter Protection For Closed Circuit Cooling TowersKatsi majan aten du wa ai hte maren, katsi ai shara ni hta nga ai shara ni hta nga ai shara ni hpe hparan ai ni gaw, ahkyak ai mayak mahkak langai hpe hkrum sha nga ai: shanhte a bungli galaw ai shara ni hta katsi ai shara ni hpe katsi ai nbung laru kaw na makawp maga ra ai. Hka gaw katsi mat ai shaloi galu kaba wa ai majaw, pipe ni kapaw mat ai, heat exchanger coil ni htum mat ai, pump ni hten za mat ai-a majaw manu dan ai gram lajang ai lam ni hte aten galu hkra galaw ra ai.

 

A matu pat da ai-circuit katsi ai nta ni,freeze hkra machyi ai lam hpe pat shingdang ai gaw gram lajang ai lam sha n re; business matut manoi galaw ai lam hte seng ai. Ndai kaw na na a cooling tower hpe winterize galaw na matu kaja dik ai ladat ni hpe tang madun da ai.

 

 

1. Glycol Dosing (Kam mai dik ai ladat)

 

Detailed Cooling Process Of Oasis Bingfeng Counterflow Closed-Circuit Cooling TowerGlycol (galaw madang hku nna propylene (sh) ethylene glycol) hpe hka lim ai hta bang dat yang, hka lim ai shara hpe shayawm kau ya ai. Ndai gaw nbung kaw na process fluid hpe garan tawn da ai majaw, pat da ai-circuit system ni a matu madang masat da ai hparan ladat rai nga ai.

 

 

 

 

Hpaji jaw ga:Glycol a n-gun hpe n-gun n law dik htum myit mada da ai grup yin nbung katsi ai hta n yawm htum 10℃F (-12℃) npu na nbung katsi ai kaw na makawp maga lu hkra tawn da ra ai.

Chyam dinglik ai lam:Glycol a n-gun hpe refractometer hte ayan jep yu nna, hka lim ai majaw (sh) hka n-gun jat ai majaw n-gun n hkrat ai hpe chye lu na matu refractometer hte ayan jep yu u.

 

2. Wan n-gun hte wan wut jak & Basin wan wut jak

 

Complete Analysis Of The Cooling Process in Oasis Bingfeng's Hybrid Flow Dual-Inlet Closed-Circuit Cooling TowerShinggan na hka garan ai ladat (nbung de hpaw da ai) a matu glycol hpe n lang chye ai. De a malai, katsi ai-hka htung hta wan jak ni hpe jung da ai.

 

 

 

 

 

 

Bungli byin ai:Ndai hka lum ai jak ni gaw hka katsi ai shara de du wa ai shaloi, shi hkum shi bungli galaw wa nna, hka htung hka hpe n-gun jaw ya ai majaw, hka lim ai pump ni bungli galaw lu ai.

Ningdung:Na a basin volume hte buga na insulation masa ni a matu, heater atsam hpe hkrak hkrak shadawn shadang tawn da ai hpe sadi u.

 

3. Kalang lang galaw ai & Drain Down

 

Working Process Of A Crossflow Closed Circuit Cooling TowerCooling tower hpe katsi majan aten hta 24/7 n galaw ra ai rai yang:

Hka lim ai:Dai system gaw aten galu n bungli galaw ai rai yang, basin hte piping yawng hpe tsep kawp hka ja kau u. Spray nozzle hte coil ni kaw na ngam ai hka hpe compressed air lang nna shapraw kau u.

Kalang lang gat ai:Load ahkang jaw yang, hka hpe n shamu shamawt hkra, system hpe aten kadun laman galaw u, raitim, off-cycles aten hta basin heater ni hpe active galaw nga ai hpe sadi ra ai.

 

4. Insulation hte Nbung hpe pat shingdang ai

 

Working Process Of A Composite Flow, Single Inlet Closed Circuit Cooling TowerKatsi ai nbung gaw katsi ai hpe sum mat ai hte katsi mat na masa hpe grai jat shangun lu ai.

Tower shingdu grup yin hta insulated panel ni hpe bang da u.

Nbung shang ai louvers ni hta nbung pat shingdang ai ni hpe lang nna, bungli galaw na matu ra kadawn ai nbung hpe naw jaw ai shaloi, nta kata de shang wa ai katsi ai nbung a n-gun hpe shayawm kau u.

 

 

 

Daw dan lam

 

Shawng nnan na hka lim ai hpe hkum la nga ai, hka lim ai hpe makawp maga na matu myit yu u. Na a nbung laru hpe jep yu ai, na a glycol level hpe chyam yu ai, na a control logic hpe ya aten hta jep yu ai gaw, hpang de jak rung ni hpe galai na matu dollar wan law law hpe hkye la lu na re.

Na a model langai a matu kaja ai glycol n-gun (sh) heater size hpe lata na matu hpaji jaw ga ra ai kun? Dai ni anhte a engineer hpung hpe matut mahkai u.

 

null

San sagawn ai lam hpe sa dat u