Nbung katsi ai hte katsi ai bungli hta pat da ai-circuit katsi ai nta ni hpe jai lang ai lam
Apr 20, 2026
Shiga hpe tawn da u
Closed-circuit cooling towers ni gaw HVAC bungli hta ahkyak ai lit nga ai, madung hku nna nbung katsi ai hka hpe nbung laru shazim ai jak ni de jaw ya ai katsi ai shara langai hku nna magam gun nga ai, dai hku nna nta ni kaw na katsi ai hpe shapraw kau ya lu ai.
I. HVAC System ni hta pat da ai-Circuit katsi ai nta ni a bungli galaw ai ladat
Nbung laru shazim ai jak langai hta, a madung bungli gaw .pat da ai-circuit katsi ai ntangu ai gaw, chiller hpe ngang grin ai, san seng ai hka katsi ai hka hpe jaw ya nna, nta kata na katsi ai hpe shapraw kau ya ai.
Bungli galaw ai lam hpe shanglawt ai ginwang lahkawng hku garan nna galaw ai:
Kata na n-gun (Process maga):
Chiller a condenser kaw na pru wa ai katsi ai hka hpe, shinggrup ai pump hku nna, pat da ai-circuit katsi ai nta a katsi galai shai ai coil ni de sa dat ai. Dai hka lum ai gaw coil ni a kata de lwi shang wa nna, hka lum ai gaw tube bunghku hku nna shinggan de htawt sit mat wa ai. Dai hka katsi mat ai gaw chiller de bai nhtang wa nna, hpaw da ai loop byin wa ai.
Shinggan na Circuit (Katsi ai maga):
Tower a lawu kaw na hka htung kaw na hka garan ai hka hpe coil ni a ntsa na distribution system de pump galaw nna shinggan coil ntsa de maren mara hka garan ai majaw hka film byin pru wa ai. Dai aten hta sha, fan langai gaw, nbung hpe tower a lawu daw kaw nna shang shangun nna, coil ntsa hku nna ntsa de lwi shangun ai. Spray hka gaw coil ntsa kaw na hka pru wa ai shaloi, hka pru wa ai latent heat law law hpe hkap la nna, coil kata na hka kaw na hka n-gun hpe htaw mat wa ai.
Katsi ai htawt sit ai lam:
Chiller hka lum ai → Coil bunghku → Hka htung → Nbung (fan kaw na pru mat ai)

II. HVAC hpaga lam hta pat da ai-Circuit Cooling Tower ni a matu laksan jai lang ai lam ni
1. Ginjaw nbung katsi ai ladat hpe katsi shangun ai
Laika shawk shawn ai lam ni:
Shawa nta kaba ni rai nga ai rung gawk ni, gat seng ni, Hotel ni, tsi rung ni zawn re ai ni hpe galaw ai.
Sanglang dan ai lam:
Pat da ai-circuit katsi ai nta ninbung n-gun shayawm ai jak (chillers) ni a matu madang masat da ai madi shadaw ai arung arai ni rai nga ai. Chiller kaw na pru wa ai katsi ai hpe katsi ai hka hku nna pat da ai-circuit katsi ai nta de htawt sit nna, shinggan de fan hku nna shapraw kau ai. N hpaw da ai cooling tower ni hte shingdaw yu yang, pat da ai-circuit tower kata na shinggrup hkawm ai hka gaw, pat da ai coil ni kata kaw bungli galaw nna, shinggan nbung hte galoi mung n matut mahkai ai. Ndai lam gaw ngang grin ai, san seng ai hka a hkam kaja lam hpe madi shadaw ya ai, chiller a condenser kata kaw scale byin wa ai hpe pat shingdang ya ai hte chiller hpe aten galu-, hkrak hkra galaw lu na matu madi shadaw ya ai.
2. Data Center ni a matu hkrak tup nbung katsi shangun ai
Laika shawk shawn ai lam ni:
Data rung ni, server nta ni.
Sanglang dan ai lam:
Data center air conditioning gaw 24/7 bungli galaw ra ai, grai tsaw ai kam hpa mai ai lam hte hka san seng ai lam hpe katsi ai jak kaw na ra sharawng ai. 2019 ning na pat da ai-loop hkrang hpepat da ai-circuit katsi ai nta nishinggan nbung hte shingjawng nga ai hka hpe pat shingdang ya ai majaw, nhpu hte bacteria ni n shang wa hkra pat shingdang ya ai. Ndai lam gaw, hkrak tup ai nbung laru shazim ai jak ni hpe aten galu-bungli galaw lu hkra galaw ya nna, hkrat sum na masa hpe mung shayawm ya lu ai.
3. Hka npawt Heat Pump Unit hpe katsi shangun ai
Laika shawk shawn ai lam ni:
Hka npawt nhpang heat pump nbung n-gun shayawm ai ladat ni.
Sanglang dan ai lam:
Counterflow hpe pat da ai-circuit katsi ai nta nin-gun n law ai hkrang hte lagaw n-gun kaji ai majaw, nbung n bung ai lam kaji ai hte hka lwi ai lam kaba ai katsi ai bungli masing ni a matu grau nna htuk manu ai. Hka n-gun law law hpe katsi shangun na matu, pat da ai-circuit tower ni hpe plant kata (sh) nta ntsa kaw tawn da mai ai majaw, loi loi hte hpawng de lu na re.

III. HVAC katsi ai lam hta Oasis Bingfeng a akyu ni
1. Chiller hpe makawp maga nna, jak rung a prat hpe jat ya ai
HVAC hpaga lam hta madung myit tsang ai lam gaw, system ngang grin ai lam hte jak rung ni a asak galu na matu re. Oasis Bingfeng apat da ai-circuit katsi ai nta nishinggan nbung kaw na tsep kawp tsan gang ai, pat da ai coil ni a kata kaw katsi ai nbung hpe shinggrup da ai, hkum tsup ai hku shinggrup da ai loop hkrang hpe jai lang u.
N san seng ai lam n nga ai:
Nbung kaw na pru wa ai nhprang wan, nhprang wan n-gun, bacteria ni gaw, hka hkawm ai hka htung kata de n shang lu ai majaw, chiller condenser hpe pat shingdang lu ai.
Scale n nga ai:
Hka hpe jasan jaseng da ai hte hpaw da ai-loop hpe lang ai gaw, calcium hte magnesium ion ni law jat wa na hpe pat shingdang ya ai majaw, pipe hte jak rung kata na bunghku ni hta scale n byin wa ai.
Stable Heat galai shai ai atsam:
Chiller gaw condenser hpe ayan n jasan jaseng ai sha, aten galu-, n-gun ja ai hku bungli galaw lu hkra galaw ya ai.
Customer a manu:
Chiller hkrat sum ai lam hpe shayawm ya ai, jak rung a prat hpe galu shangun ai, gram lajang ai manu hpe grai shayawm ya ai.
2. Hpaji rawng ai nbung katsi ai hpe hkang lu ai, AC Load hte hkrak hkrak bung ai
Oasis Bingfeng a pat da ai-circuit katsi ai nta ni hta, nbung katsi ai jak a tengman ai lit hpe madung tawn nna, bungli galaw ai lam hpe shi hkrai shi gram lajang ya ai hpaji rawng ai digital katsi ai hpe hkang ai ladat hpe lang da ai.
Tinang hkrai hpang/jahkring ai hpe hkang ai:
Hka pru ai hka n-gun hpe madung tawn nna, bungli galaw ai fan ni a jahpan hte spray pump a on/off masa hpe shi hkrai shi hkang lu ai.
Galai shai ai Frequency hpe galai shai ai (Ra sharawng ai):
Tengman ai hku lwi ai hpe hkang lu na matu hkang ai valve ni hpe jung da nna, ra ai hku katsi shangun ai.
Tinang hkum tinang Dual-Mode galai ai:
Hpa majaw nga yang, bungli galaw ai masa, aten ladaw, hka n-gun nga ai hpe madung tawn nna, hka lim ai hte hka lim ai bungli galaw ai ladat ni hpe shi hkrai shi galai shai ya ai.
Customer a manu:
AC system a matu shaning shagu na n-gun lang ai lam hta kaja dik htum, "gumra kaba langai mi gaw leng kaji hpe gang ai" kaw na n-gun hpe jahten kau ai hpe koi gam ai.

3. Hka hpe grai hkye la lu ai, bungli galaw ai manu hpe shayawm lu ai
Nbung n-gun shayawm ai jak ni a matu, hka jai lang ai lam gaw aten galu-bungli galaw ai manu jahpu a madung daw langai rai nga ai. Oasis Bingfeng apat da ai-circuit katsi ai nta nihka hpe makawp maga ai lam hta grau kungkyang ai.
Zero kata na loop jai lang ai lam:
Hka shinggrup ai gaw, pat da ai coil ni kata kaw bungli galaw nna, hka lim ai lam (sh) sum ai lam n nga ai.
Spray Hka hpe bai jai lang ai lam:
N--hpyen n-gun n rawng ai hka hpe drift eliminators ni hte bai hkap la nna, bai jai lang na matu basin de bai nhtang bang ai.
Hka lum ai aten hta Hka Zero lang ai:
Shinggan nbung katsi ai aten hta, hka garan ai ladat hpe tsep kawp pat kau lu ai, fan-driven air cooling hpe sha kam hpa nna, hka zero jai lang ai lam hpe lu la mai ai.
Customer a manu:
Hpaw da ai nta npawt ni hte shingdaw yang shaning shagu hka hpe 50% jan hkye la lu ai, grau nna hka-n law ai ginra ni (sh) hka manu grai tsaw ai shara ni hta akyu rawng ai.
4. Katsi ai hku katsi ai hpe shapraw kau ya ai, AC hpe katsi shangun ai bungli hpe kam hpa ya ai
AC system langai a katsi ai atsam gaw katsi ai nta a katsi ai hpe shapraw kau lu ai atsam hta madung nga ai. Oasis Bingfeng apat da ai-circuit katsi ai nta nihybrid flow hpe jai lang nna, -htuk manu ai nbung galai shai ai hkrang hpe jai lang u.
Dual katsi ai ladat:
Nbung katsi ai hte spray evaporative katsi ai, nbung katsi ai sha hta grau nna nbung galai shai ai atsam hpe lu la ai.
Coil hpe kaja dik htum lajang da ai:
Unit volume langai hta nbung galai shai ai shara hpe jat ya ai majaw, nbung galai shai ai coefficient grai law wa ai.
Mali-Nbung shang ai hkrang shapraw ai lam:
Nbung hpe ninghkap ai lam hpe shayawm ya ai, fan power ra ai lam hpe shayawm ya ai, nsen hpe mung shayawm ya ai.
Hkrak ai Cooling Margin:
Ra kadawn ai shimlam masat masa ni hpe grau sawng ai grup yin masa ni hte bungli galaw ra ai lam ni hpe hkap la lu na matu hkrang shapraw ai hta bang da ai.
Data madi shadaw ai lam:
Oasis Bingfeng gaw 21 ning jan hpaji ninghkring ni a galaw shapraw ai mahkrum madup hte patent galaw da ai hpaji masa 23 hpe lu da ai; n-gun madun ai lam hpe market- hta jep joi ai lam galaw ai.
Customer a manu:
AC system gaw katsi ai nbung laru aten hta pyi kam hpa mai ai hku bungli galaw nna, katsi ai hpe tup hkrak hkam la lu ai.
5. Eco-Hkau chyap ai hte nsen n law ai, Green Building ra kadawn ai lam ni hpe hkan sa ai
Ya aten na nta ni hta grup yin hpe makawp maga na matu hte nsen hpe hkang lu na matu grai ngang kang ai tara ni nga ai. Oasis Bingfeng apat da ai-circuit katsi ai nta nindai kaw asan sha akyu ni hpe jaw u.
Drift sum ai lam n law ai:
Hka n-gun yawm mat ai hpe shayawm lu na matu, -hkum tsup ai drift eliminators ni hpe lang ai.
Nsen kaji ai hkrang shapraw ai lam:
Kaja dik htum hkrang shapraw da ai, ngang kang ai, kam mai ai nta npawt gaw, bungli galaw ai shaloi grai n-gun yawm hkra galaw ya ai.
Chemical n san seng ai:
Ndai closed loop gaw hka hpe jasan jaseng ai tsi ni hpe shayawm ya ai majaw grup yin hpe grau shim lum hkra galaw ya lu ai.
Aesthetic hkrang bung sumla:
Hpaji masa hku galaw da ai shinggan n-gang hte 304 n-gun n rawng ai n-gang (sh) magnesium{1}}aluminum-zinc coated n-gang hte galaw da ai, dai ni na nta ni a matu htuk manu ai, n-gun rawng ai, myit htuk ai hkrang hpe jaw ya ai.
Customer a manu:
Green building jep joi ai madang ni hpe hkan sa nna, tsi rung, hotel, rung nta zawn re ai nsen-hkam sha ai shara ni a matu htuk manu ai.

San sagawn ai lam hpe sa dat u