Data Center ni hta pat da ai-Circuit katsi ai nta ni hpe jai lang ai lam

Mar 04, 2026

Shiga hpe tawn da u

2019 ning na jai lang ai mabyin masa ni.Pat da ai-Circuit katsi ai nta niData ginjaw ni hta

Data center kata kaw bungli galaw ai server ni gaw, grai law hkra katsi ai hpe shapraw ya ai majaw, shaning ting 24/7 n hkring n sa katsi ai hpe ra ai, dai gaw, jak rung ni a bungli galaw ai nbung katsi ai lam hpe n-gun jaw na matu (22℃grup yin hta hkang lu ai).

Shanhte a n-gun atsam grai kaja ai hte n-gun-hkye la lu ai atsam a majaw, pat da ai-circuit katsi ai nta ni gaw data center katsi ai ladat ni a ahkyak ai daw langai byin wa nga ai.

Oasis Bingfeng Closed-Circuit Cooling Tower

Data center kaw na pru wa ai hka n-gun hpe 1990 ning na hka n-gun galai shai ai coil ni de sa ya ai.pat da ai-circuit katsi ai nta, ngu nna katsi mat ai hpang, data center de bai sa dat ai.

Spray hka hpe coil ni a shinggan de garan jaw nna, fan ni gaw nbung hpe hkap la ai. Nbung gaw coil ni hku lai wa ai shaloi, katsi ai hpe htaw mat wa nna, hka lim ai hka a hka lim ai gaw katsi ai lam hpe grau nna jat ya ai.

Data center ni a hkrak ai mabyin masa a matu, Oasis Bingfeng gaw, lam masum kaw nna sung ai hku gram lajang ai lam hpe lu la ai:

1. Tinang ra sharawng ai hkrang shapraw ai lam

Data center a jung da ai shara hpe madung tawn nna, counterflow, hpawng de ai, crossflow zawn re ai structure amyu myu hpe mai lang ai.

N bung ai ginra grup yin masa ni hpe hkan nna, laksan galaw da ai anti-hten run ai hparan ladat ni:

Hka hkin gau na Data Ginjaw ni:Hka lim ai n-gun hpe ninghkap lu ai atsam hpe jat ya lu na matu, super galvanized coating (sh) magnesium-aluminum -zinc hte shinggrup da ai plate shells ni hpe jai lang ai.

Arid Ginra ni:Katsi ai hpe shapraw kau lu ai atsam hpe grau kaja hkra galaw na matu structural design hpe grau kaja hkra galaw ai.

2. Hpaji rawng ai hku hkang zing ai ladat

Data center a load arawn alai ni hpe madung tawn nna, kaja dik ai start/stop ladat ni hpe gawgap ya ai, laksan galaw da ai hpaji rawng ai hkang zing ai ladat ni hpe gram lajang ai.

Spray pump hte fan ni hpe katsi ai shara a nbung katsi ai hte maren, hpaw hpang ai hte jahkring kau ai hpe shi hkrai shi hkang lu ai.

Remote monitoring galaw ai lam gaw, client ni hpe gara aten, gara shara kaw raitim, jak rung bungli galaw nga ai masa hpe chye lu shangun ai.

3. Magam bungli galaw ai ladat hpe grau kaja hkra galaw ai

Data center ni a n-gun kaba ai hkam sha lam hpe hparan ai hku nna, on-ra sharawng ai katsi ai lam hpe lu la na matu, galai shai ai frequency system ni hpe gram lajang ai.

Oasis Bingfeng Evaporative Condenser

Hka n-gun nga ai hpe madung tawn nna, dry/wet mode galai shai ai ladat ni hpe grau kaja hkra galaw ai, bungli galaw ai manu hpe shayawm kau ai sha n-ga, katsi ai bungli hpe mung galaw lu ai.